Emergency Medical Devices patient monitor portable

FOB Reference Price:Get Latest Price
$400.00 / Units | 1 Unit/Units patient monitor portable (Min. Order)
Report Suspicious Activity
Overview
Quick Details
Brand Name:
Ysenmed
Model Number:
YSF5
Place of Origin:
Guangdong, China
Model name:
patient monitor portable
LCD:
10.4'' color TFT
NIBP:
750 groups NIBP measurement
Patient range:
Adult, neonate and pediatric patients
Power Supply:
AC 100-240V 50/60HZ
Power:
AC and DC
Dimension:
318mmx264mmx152mm
Weight:
4.5Kgs (with battery)
Warranty:
1 Year
Certificate:
CE ISO
Type:
Examination Therapy Equipments
Supply Ability
Supply Ability:
1000 Unit/Units per Month patient monitor portable
Packaging & Delivery
Packaging Details
Emergency Medical Devices patient monitor portable
standard exporting packing
Port
Guangzhou
Lead Time :
3

Emergency Medical Devices patient monitor portable

 

 

Features

 

 

¨ 12.1' color TFT LED screen supports display max. 8 waveforms  

 

¨ Visual On-display and integrated alarm light  

 

¨ Display mode: standard, large font, trend table, OxyCRG, full leads ECG 

 

¨ Arrhythmia analysis and real-time S-T segment analysis and pacemaker detection 

 

¨ Drug calculation, titration table

 

¨ Suitable for monitoring adult, pediatric and neonatal patient. 

 

¨ Extended advance function: 2IBP, Depth of Anesthesia, EtCO2 , Nellcor SpO2 

 

 

Standard Configuration:

 

¨ Anti-glare screen, Large capacity rechargeable battery,  3/5-Lead ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature

 

Optional Configuration:

 

¨ Dual IBP, Nellcor SpO2, MASIMO SpO2, Depth of Anesthesia Monitoring Module, 

 

 

EtCO2 (Main-stream/Side-stream)

 

¨ Thermal printer (50 mm)

 

 

¨ Pediatric / neonatal accessories: reusable NIBP cuff & SpO2 probe; disposable NIBP cuff & 

 

SpO2 probe

 

¨ Central Monitoring System

 

¨ Touch Screen

 

 

¨ Trolley/Wall Mount

 

 

Physical Specifications

Dimension and weight

Dimension

340mm(W)*280mm(H)*130mm(D)

Weight

Standard configuration: 4 kg

Operation environment

Power requirements

AC 100-240V, 50/60HZ, 60W

Power

90VA

Temperature

0-40

Humidity 

0-93% non-condensing

Safety

Meet the requirements of IEC60601 series

Patient range

Adult, neonate and pediatric patients

Performance Specification

Display                            

12.1’ (800 x 600 pixel) color TFT LEscreen

Display mode

Standard, big font, trend table, full-lead ECG, Oxy CRG.

Interface

 

Parameter cable interface 

AC power input socket 

Network interface 

Battery

1 internal large capacity rechargeable lithium battery

Alarm indicator

Visual on-display and integrated alarm light

Audible alarm 

Data storage

 

108 hour trend graph

168 hour trend table 

2 hour trend wave  

1024 alarm events  

Printer

 

 

Built-in 50mm thermal printer (option),  

3 traces, print speed 12.5mm/s & 25mm/s & 50mm/s    

Print width: 50mm

Net working 

Support connection to central monitoring station 

through LAN (TCP/IP) or wireless connection   

ECG

Leads type 

3/5 lead : I, II, III, aVR, aVL, aVF, V

Sweep speed

12.5mm/s, 25mm/s,50mm/s

Gain selection

×0.25×0.5, ×1, ×2, Auto

ECG waveform

2 channels

Operation mode

Diagnostic, monitor, surgery

Heart rate range

- 350bpm

Accuracy

1bpm or ±1% whichever is great 

Alarm range

Audible and visual alarm, adjustable

ST/ arrhythmia

Real time S-T 

segment detection,pace detection and arrhythmia analysis 

Protection

Against electrosurgical interference and defibrillation

Respiration (RESP)

Method

Thoracic impedance

Operation mode 

Auto

Measurement range

Adult: 0-120BrPM; neonatal /pediatric: 0-150BrPM

Apnea alarm

Yes

Alarm

Yes, audible and visual alarm ,alarm events recallable

NIBP

Method

Automatic oscillometric

Operation mode

Manual / Automatic / STAT

Auto measure time 

Adjustable 

Measurement unit

mmHg / kPa  selectable

Test interval

1-480 minutes

Measurement range

 

 

Adult: 0-300 mmHg ;     

Child: 0-240 mmHg ;      

Infant: 0-150 mmHg

Over-pressure protection 

Double safety protection 

Accuracy of blood pressure  measurement

The mean error shall be less than ± 5mmHg

The standard deviation shall be less than 8mmHG

Resolution

1 mmHg

SPO2

Measurement range

0%-100%

Resolution

1%

Accuracy

±2% (70-100%, adult/pediatric, non-motion )

±3% (70-100%, neonate, non-motion )

±3% (70-100%, adult/pediatric/neonate, motion )

0-69% unspecified

Alarm range

1-100%

Pulse rate                          

Pulse range:

0-350bpm

Accuracy:

±3bpm(non-motion)

±5bpm(motion )

Temperature (TEMP)

TEMP range

0-50

Resolution

0.1 

Accuracy

±0.1  (excluding the sensor)

Channel

Dual-channel. provide T1;T2; T

IBP

Measurement range

-50-360mmHg

Channel

2 channels 

Pressure transducer

Sensitive :5 uV/V mmHg

Impedance range :300-3000 Ω 

Pressure names

ART, PA, CVP, RAP, LAP, ICP, P1, P2

Alarm range

-10-300 mmHg

PR from IBP

Range & Accuracy:

25 -200bpm  ±1bpm or ±1bpm which is 

greater 201-350bpm ±2%

Resolution :

1bpm

Depth of Anesthesia (BIS) 

EEG sensitivity

+/- 475μV

Noise

< 2uVp-p (1-150 Hz)

CMRR

> 100 dB

Input impedance

> 50mohm

Sample rate

1024 samples/s, 16 bits

 

 

 

Interface

 

 

Upright Handle, Easy to carry

 

 

 

Transducer Socket (Switzerland LEMO socket)

 

 

 

Control Panel & Color LED Display (7 hotkeys & Japan SHARP LED)

 

 

 

 

 More patient monitor for choice:

 

 

YSF6

 

 

YSF8

 

 

YSF8-S

 

 

 

 

 

YSF15

 

Contact me to let me know your specfic request.

 

Contact Person:Sophie Lin

 

Mob:+86 15876599362 (whats app also available)

 

Skype: ysenmed-016

 

E-mail also welcome!